Management of iatrogenic right ventricular puncture: A case report
Main Article Content
Keywords
Right ventricular puncture, drainage, management
Tóm tắt
A 100-year-old female patient was admitted for a pericardial effusion with unknown etiology. Pericardiocentesis was performed and the pigtail drainage catheter was noted to be in the right ventricle and not pericardial space. A separate pigtail catheter was placed in the pericardial space and the existing pigtail catheter was removed under close hemodynamic monitoring. The patient subsequently stabilized. This case demonstrates that puncture of the right ventricle may be treated conservatively.
Article Details
Các tài liệu tham khảo
1. Inglis R, King AJ, Gleave M, Bradlow W, Adlam D (2011) Pericardiocentesis in contemporary practice. J Invasive Cardiol 23(6): 234-239.
2. Kumar R, Sinha A, Lin MJ, Uchino R, Butryn T, O'Mara MS et al (2015) Complications of pericardiocentesis: A clinical synopsis. Int J Crit Illn Inj Sci 5(3): 206-212.
3. Oda T, Kono T, Akaiwa K, Takahara Y, Yasuoka C, Nakamura K (2017) Surgical repair of subacute right ventricular perforation after pacemaker implantation. Case Rep Cardiol: 3242891.
4. Petrov I, Dimitrov C (2009) Closing of a right ventricle perforation with a vascular closure device. Catheter Cardiovasc Interv 74(2): 247-250.
5. Stolt V, Cook S, Räber L, Wani S, Garachamani A, Vogel R et al (2012) Amplatzer septal occluder to treat iatrogenic cardiac perforations. Catheter Cardiovasc Interv 79(2): 263-270.
2. Kumar R, Sinha A, Lin MJ, Uchino R, Butryn T, O'Mara MS et al (2015) Complications of pericardiocentesis: A clinical synopsis. Int J Crit Illn Inj Sci 5(3): 206-212.
3. Oda T, Kono T, Akaiwa K, Takahara Y, Yasuoka C, Nakamura K (2017) Surgical repair of subacute right ventricular perforation after pacemaker implantation. Case Rep Cardiol: 3242891.
4. Petrov I, Dimitrov C (2009) Closing of a right ventricle perforation with a vascular closure device. Catheter Cardiovasc Interv 74(2): 247-250.
5. Stolt V, Cook S, Räber L, Wani S, Garachamani A, Vogel R et al (2012) Amplatzer septal occluder to treat iatrogenic cardiac perforations. Catheter Cardiovasc Interv 79(2): 263-270.